20% OFF shipping at wi-eau.fr on orders over $79 + up to 10% OFF products
wi-eau.fr
home > Wilkins 212-ZW209BP | Pilot Operated PRV with Low Flow By-Pass, 2-1/2 Inches > Wilkins 212-ZW209BP | Pilot Operated PRV with Low Flow By-Pass, 2-1/2 Inches
download picture
Wilkins 212-ZW209BP | Pilot Operated PRV with Low Flow By-Pass, 2-1/2 InchesNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 212 ZW209BP is a pilot operated pressure reducing valve with integrated low flow bypass, designed for high inlet pressure reduction to stable outlet pressure in commercial and industrial water systems. Key Specifications: Size: 2 1 2 Inches Pilot Spring Range: 15120 psi Temperature Rating: 33F to 140F Notable Certifications: NSF ANSI
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 212-ZW209BP is a pilot-operated pressure reducing valve with integrated low-flow bypass, designed for high inlet pressure reduction to stable outlet pressure in commercial and industrial water systems.

 

Key Specifications:

  • Size: 2 1/2 Inches
  • Pilot Spring Range: 15–120 psi
  • Temperature Rating: 33°F to 140°F
  • Notable Certifications: NSF/ANSI 61 compliant
  • End Connections: ANSI Class 150 Flanged

 

Other Related Variants:

  • 112-ZW209BP: 1 1/2 Inches valve size
  • 2-ZW209BP: 2 Inches valve size
  • 3-ZW209BP: 3 Inches valve size
  • 4-ZW209BP: 4 Inches valve size

 

Materials:

  • Ductile iron body (ASTM A536)
  • Ductile iron bonnet (ASTM A536)
  • Stainless steel disc guide
  • Stainless steel seat
  • Stainless steel stem
  • Stainless steel spring
  • Buna-N rubber disc
  • Nylon reinforced Buna-N diaphragm
  • Blue epoxy coating (FDA approved)
  • Copper tubing and brass fittings

 

Typical Installation:

The Zurn 212-ZW209BP is commonly used in buildings where 1-15 GPM low flows are common during off-peak usage. The valve is designed for applications requiring reduction of high inlet pressures to safe and stable outlet pressure with the ability to handle very low flows up to 10 GPM through the integrated low-flow bypass when the main valve closes during off-peak demand periods.

 

Standards Compliance:

ANSI/AWWA C530; NSF/ANSI/CAN 61 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)

 

Features & Benefits:

  • Integrated Low-Flow Bypass: Handles flows up to 10 GPM during off-peak demand without opening the main valve, ensuring continuous pressure control.
  • Complete Control Package: Includes wye strainer, isolation valves, inlet/outlet pressure gauges, and all necessary pilotry for immediate installation and operation.
  • Corrosion Protection: FDA-approved blue epoxy coating on all internal and external ferrous surfaces provides long-term durability and corrosion resistance.
  • Precision Pressure Control: Pilot-operated design modulates main valve position to maintain constant downstream pressure within 15-120 psi adjustable range.

 

FAQ

 

Q: What is the minimum inlet pressure required for the Wilkins 212-ZW209BP to operate properly?

A: The minimum inlet pressure is 10 psi higher than the set point or the additional body friction loss at intended flow, whichever is higher.

Q: How does the low-flow bypass function on the Zurn 212-ZW209BP?

A: The low-flow bypass is preset to a slightly higher pressure than the main pilot control. When the main valve closes due to low demand, the bypass valve remains open to handle flows up to 10 GPM, closing only when downstream pressure reaches its set point.

Q: Can the 212-ZW209BP be installed in any orientation?

A: The recommended installation orientation is horizontal with the valve cover up. This ensures proper air bleeding and facilitates maintenance procedures.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 212-ZW209BP | Pilot Operated PRV with Low Flow By-Pass, 2-1/2 Inches

Item no : 99300839491
sold recently : Login >>
US$ 2949.49
Pay in 4 interest-free payments of $737.37 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 19 - Jul 24

Enjoy 20% off shipping

US$ 2949.49

1-11

US$ 2654.54

12-35

US$ 2064.64

36-59

US$ 1769.69

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches