8237-1369 Woodward ProTech-GII Datasheet & Technical ManualWoodward 8237 1369 ProTech GII Overspeed Protection System The Woodward 8237 1369, also cataloged as the 8237 1369 Overspeed Protection System, operates as a dedicated hardware component for fail safe speed monitoring within gas, steam, and hydro turbine platforms. Hardware Specifications Parameter Specification Model 8237 1369 Brand Woodward Origin USA Weight 6. 5 kg (14. 3 lbs) Dimensions Standard ProTech GII rackmount chassis footprint Operating
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 8237-1369 ProTech-GII Overspeed Protection System

The Woodward 8237-1369, also cataloged as the 8237-1369 Overspeed Protection System, operates as a dedicated hardware component for fail-safe speed monitoring within gas, steam, and hydro turbine platforms.

Hardware Specifications

Parameter Specification
Model 8237-1369
Brand Woodward
Origin USA
Weight 6.5 kg (14.3 lbs)
Dimensions Standard ProTech-GII rackmount chassis footprint
Operating Temp -40 to +85 deg C
Power Consumption Configured via dual redundant 24 VDC inputs (18-32 VDC range)
Voting Logic 2-out-of-3 (2oo3) Triple Modular Redundant (TMR)
Response Time < 12 ms typical
Speed Sensing Inputs 3 x Independent passive or active MPU inputs
Relay Outputs Trip relays (Form A/C), alarm relays
Analog Outputs Configurable 4-20 mA speed readouts
Communication Protocols Modbus RTU (RS-485) and Modbus TCP (Ethernet)
Enclosure Rating IP56
EMC Compliance EN61000-6-2 (Immunity), EN61000-6-4 (Emissions)

Industrial Drives, Governors, and Speed Control Properties

The device processes high-resolution frequency profiles from three independent magnetic pickups to regulate trip relay states on critical rotating assets. The 2-out-of-3 (2oo3) voting logic structures the internal actuator loop feedback response time limits, achieving a sub-12 ms instantaneous trip response upon registering an overspeed threshold breach. To insulate the processing core from high-frequency electromagnetic interference generated by industrial drive infrastructure, the unit integrates internal harmonic distortion suppression modules alongside EN61000-6-2 certified shielding layers. Thermal heat sink dissipation profiles across the IP56-rated housing maintain steady-state logic tracking without introducing processing lag under continuous maximum temperature environments.

Frequently Asked Questions

Q: How does the internal 2oo3 voting logic isolate a single sensor failure without tripping the prime mover?

A: The Triple Modular Redundant (TMR) architecture continuously runs independent speed tracking algorithms on all three MPU inputs. If one sensor goes offline or transmits erroneous values, the internal 2oo3 logic overrides the single fault, allowing the remaining two channels to maintain protection monitoring and eliminate nuisance trips.

Q: Can the automated periodic self-tests be executed while the turbine is online?

A: Yes. The hardware executes internal self-testing routines that verify the electrical and functional integrity of the trip relays and internal logic boards. These procedures are conducted safely while the asset remains in service, without risking an accidental shutdown.

Q: What are the parameters for dual power input redundancy on this system?

A: The device contains separate, isolated power terminals designed to accept dual redundant 24 VDC nominal lines. The hardware functions continuously across an 18 VDC to 32 VDC range, executing automatic, bumpless switchover if one power source experiences a localized dropout.

Field Installation Guidelines

  • MPU Terminal Shielding Constraints: Route the three independent magnetic pickup lines using dedicated twisted-pair, shielded cables. Terminate each cable shield exclusively at the designated ground bar on the ProTech-GII chassis to minimize electrical cross-talk and maintain clean input signals.
  • IP56 Enclosure Sealed Routing: To maintain the IP56 ingress protection rating against dust and high-pressure water jets, use liquid-tight conduit hubs or compression glands for all cable entries into the terminal cabinet. Seal any unused entry ports to prevent moisture accumulation.
  • Network Communication Separations: Install Modbus TCP Ethernet and Modbus RTU RS-485 cables in separate low-voltage wire trays away from the primary trip relay outputs and heavy AC power lines to safeguard data transmission interfaces from inductive noise.

8237-1369 Woodward ProTech-GII Datasheet & Technical Manual

Item no : 88619886474
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 7 - Sep 12

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches