Wilkins 6-ZW209FPG | 6" Fire Protection Pressure Reducing Valve, Grooved EndsNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 6 ZW209FPG is a pilot operated pressure reducing valve designed for fire suppression systems, delivering stable downstream pressure control regardless of flow rate or inlet pressure variations. Key Specifications: Valve Size: 6 Inches Inlet Pressure Rating: 300 psi grooved Temperature Rating: 33F to 140F water Notable Certifications:
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 6-ZW209FPG is a pilot-operated pressure reducing valve designed for fire suppression systems, delivering stable downstream pressure control regardless of flow rate or inlet pressure variations.

 

Key Specifications:

  • Valve Size: 6 Inches
  • Inlet Pressure Rating: 300 psi grooved
  • Temperature Rating: 33°F to 140°F water
  • Notable Certifications: UL and C-UL Listed
  • End Connections: Grooved ends (300 psi)

 

Other Related Variants:

  • 2-ZW209FPG: 2 Inches valve size
  • 212-ZW209FPG: 2 1/2 Inches valve size
  • 3-ZW209FPG: 3 Inches valve size
  • 4-ZW209FPG: 4 Inches valve size
  • 8-ZW209FPG: 8 Inches valve size
  • 10-ZW209FPG: 10 Inches valve size

 

Materials:

  • Ductile Iron body (ASTM A536)
  • Ductile Iron cover (ASTM A536)
  • Stainless Steel disc guide
  • Stainless Steel seat
  • Buna-N rubber disc
  • Nylon reinforced Buna-N diaphragm
  • Stainless Steel stem
  • Stainless Steel spring
  • Red epoxy coating (FDA approved, internal and external)
  • Copper tubing and brass fittings

 

Typical Installation:

The upstream and downstream pressure gauges are required by Underwriters Laboratories (UL). A relief valve of not less than 1/2 inch in size MUST be installed on the downstream side of the pressure control valve. Adequate drainage for the relief valve discharge must be provided. The valve should be installed in accordance with NFPA 13 or NFPA 14 standards. The recommended installation orientation is horizontal with the valve cover up. 6 inch and larger valves should only be installed horizontally with the valve cover up due to the difficulty of properly bleeding air out of the cover and performing maintenance on valves installed in the vertical orientation.

 

Standards Compliance:

ANSI/AWWA C530; AWWA C606; ANSI B1.20.1; NFPA 13; NFPA 14; NFPA 25; UL Listed; C-UL Listed

 

Features & Benefits:

  • Pilot-Operated Precision Control: The Zurn 6-ZW209FPG maintains constant downstream pressure independent of flow rate changes, ensuring reliable fire protection system performance.
  • Complete Ready-to-Install Package: Includes wye strainer, inlet and outlet pressure gauges with 3-way isolation valves for quick installation and easy field adjustment.
  • Superior Corrosion Protection: Red FDA-approved epoxy coating on all internal and external ferrous surfaces provides long-lasting durability in fire suppression applications.
  • UL Listed Reliability: The Zurn 6-ZW209FPG meets stringent UL and C-UL requirements for fire protection systems, with adjustable pilot range from 50 to 165 psi residual pressure.

 

FAQ

 

Q: What is the adjustable pressure range for the Wilkins 6-ZW209FPG pilot control?

A: The pilot control is field adjustable from 50 psi to 165 psi residual pressure, with a maximum static pressure rating of 175 psi.

Q: What are the minimum and maximum flow rates for the 6 inch model?

A: The minimum flow rate is 10 GPM, with a minimum flow rate to set the valve of 220 GPM. The maximum flow rate is 2250 GPM based on schedule 40 pipe at approximately 20 ft/sec continuous flow.

Q: Can the valve be installed vertically?

A: The recommended installation orientation is horizontal with the valve cover up. 6 inch and larger valves should only be installed horizontally due to difficulty properly bleeding air and performing maintenance when installed vertically.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 6-ZW209FPG | 6" Fire Protection Pressure Reducing Valve, Grooved Ends

Item no : 22675045242
sold recently : Login >>
US$ 4435.99
Pay in 4 interest-free payments of $1109.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 19 - Jul 24

Enjoy 20% off shipping

US$ 4435.99

1-11

US$ 3992.39

12-35

US$ 3105.19

36-59

US$ 2661.59

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches